Omnilux Contour FACE LED Mask — Clinical Study Summary (PM 00043 07-20)
Source read by Luma Index (results not verified)Studied: This exact mask Not peer-reviewed
Single-group, open-label before-vs-after consumer trial; no control or sham group. Photo grading described as 'blinded investigator assessment' · 28 participants
What it measured and its limits
Measured: Visioscan SELS smoothness −38.7%, wrinkles −37.6%, scaliness −20.6%; Cutometer elasticity +29.3% and Corneometer hydration +19.4% at week 5; no significant pigmentation change; self-assessment questionnaires. No statistical tests or p-values reported
- No control or sham group
- Small sample (25 completers), almost all women, mostly skin type III
- Hydrogel mask used during treatment, so effects cannot be attributed to light alone
- Brand-authored summary, not a full report; investigators and site not named; no statistics
- Self-assessment percentages differ from figures used in marketing
- Device version tested in 2018 not stated